Electric Motors

AC B14 MOTORS

This component of fundamental importance in the definition of hydraulic mini power pack, must meet strict requirements of electrical power, in order to meet the demands of hydraulic power. The sizing of the electric motor is achieved by considering the following parameters: pump flow, pressure work and performance of the component. Different is the speech about the voltage, which must clearly meet the target of machinery where the hydraulic power pack going to be housed. The range of engines provides both the three and single-phase. Only one coupling B14 is available to allow the binding to the central manifold, through our connection kits.

Electric motors dimensions

S1 - CONTINUOUS RUNNING DUTY

Once started, the motor works at the constant load at least until thermal equilibrium is reached. Then that motor may be operated for an unlimited period.
Motors with duty S1 are included in high efficiency European regulation.

IP 55 50Hz - Single-phase - S1

Code

Power

Size

A

ØB

C

Size

Power

Code

2 POLES 4 POLES
MM 711-2 0,37 71 211 147 125 71 0,25 MM 711-4
MM 712-2 0,55 71 211 147 125 71 0,37 MM 712-4 
MM 801-2 0,75 80 250 163 146 80 0,55 MM 801-4 
MM 802-2 1,1 80 250 163 146 80 0,75 MM 802-4 
MM 90S-2 1,5 90 262 183 153 90 1,1 MM 90S-4 
MM 90L-2 2,2 90 287 183 153 90 1,5 MM 90L-4 
– – – 309 205 165 100 2,2 MM 100L1-4 

IP 55 50Hz - Three-phase - S1

Code

Power

Size

A

ØB

C

Size

Power

Code

2 POLES 4 POLES
MT 711-2 0,37 71 211 147 115 71 0,25 MT 711-4
MT 712-2 0,55 71 211 147 115 71 0,37 MT 712-4
MT 801-2 0,75 80 250 163 133 80 0,55 MT 801-4
MT 802-2 1,1 80 250 163 133 80 0,75 MT 802-4
MT 90S-2 1,5 90 262 183 139 90 1,1 MT 90S-4
MT 90L1-2 2,2 90 287 183 139 90 1,5 MT 90L1-4
MT 100L1-2 3 100 309 205 152 100 2,2 MT 100L1-4
MT 100L2-2 4 100 309 205 152 100 3 MT 100L2-4
MT 112L1-2 5,5 100 330 221 155 100 4 MT 112M-4
–  – – 330 221 155 100 5,5 MT 112L1-4

S3 - INTERMITTENT PERIODIC DUTY

A sequence of identical duty cycles, made up with a time of operation at costant load and a time at rest. When at rest, the motor is not fed.
Starting current does not significantly influence temperature rise. Unless otherwise specified, the duration of a cycles for S3 duty shall be 10 minutes and the cycle duration factor shall be one of the following values: 15%, 25%, 40%, 60%.
The duty type S3 share a time to rest (no external load is applied) during which the motor lowers its temperature, thus affording to overload such motor with respect to the same motor when loaded with S1 duty cycles (then continuosly loaded). Moreover motors with duty types different from S1 are not included in high efficiency European regulation.

IP 55 50Hz - Single-phase - S3

Code

Power

Size

A

ØB

C

Size

Power

Code

2 POLES 4 POLES
MM3711-2 0,75 71 250 163 146 71 0,55 MM3711-4
MM3712-2 1,1 71 250 163 146 80 0,75 MM3801-4 
MM3801-2 1,5 80 262 183 153 80 1,1 MM3802-4 
MM390L-2 2,2 90 287 183 153 90 1,5 MM390S-4 
– – – 309 205 165 90 2,2 MM390L-4 
– – – 327 205 165 100 3 MM3100L1-4

IP 55 50Hz - Three-phase - S3

Code

Power

Size

A

ØB

C

Size

Power

Code

2 POLES 4 POLES
MT3711-2 0,37 71 211 147 115 71 0,25 MT3711-4
MT3712-2 0,55 71 211 147 115 71 0,37 MT3712-4
MT3801-2 0,75 80 250 163 133 80 0,55 MT3801-4
MT3802-2 1,1 80 250 163 133 80 0,75 MT3802-4
MT390S-2 1,5 90 262 183 139 90 1,1 MT390S-4
MT390L1-2 2,2 90 287 183 139 90 1,5 MT390L1-4
MT3100L1-2 3 100 309 205 152 100 2,2 MT3100L1-4
MT3100L2-2 4 100 309 205 152 100 3 MT3100L2-4
MT3112L1-2 5,5 100 335 229 167 100 4 MT3112M-4
–  – – 335 229 167 100 5,5 MT3112L1-4

Further information can be found in IEC 60034-1 Standard

The technical characteristics, dimensions and other data are not bindings. Gazzera S.r.l. reserve the right to change them or modify them at any time without notice.